Solution for airborne and impact noises. Hanger TYPE C fixed to the existing joists with battens 50 mm. Easyfit 50 mm slabs fitted between battens. 19 mm sound plank to be fitted to the new joists, all joists scaled with acoustic mastic. To finish add a final layer of acoustic plasterboard.
17 db reduction in airborne noise*
19 db reduction in impact noise*
3 inch ceiling height loss
Solution for airborne and impact noises, in use when we can’t lose too much space. First step: the existing ceiling needs to be removed. The AMW 100 is fitted between joist and resilient bars fixed to the joist, 19 mm sound to be fixed to the joist, all joists sealed with acoustic mastic. To finish we add a final layer of acoustic plasterboard.
The best solution for impact noise. Build up new ceiling joists with 20-30 gap from existing ceiling, the AMW 100 is fitted between new joists. Resilient bars are fixed to the resilient bars, all joists sealed with acoustic mastic. To finish we add final layer of acoustic plasterboard.
26 db reduction in airborne noise*
26 db reduction in impact noise*
7-8 inch ceiling height loss
*the actual noise reduction depends on the building structure







Designed by Open Gate Technology